021-64306523
ǰλã > 늙CƷ > CEMP늙C

늙CƷ

Motor brand

CEMP 늙C

QCEMP  늙C
S        ң
b        أ

 

CEMP˾1954꣬ȫķ늙CƷƣOm{磨SENAGO늙CI֮һ
^낀oĄDΣCEMPFѽɞȫ늙CIIߣ_lȫϵеđΣUϵķ늙Cṩɲ܇늙C׃l늙Cpٷ늙Cط늙Cۉm늙CL늙C늙Co늙CطN늙C⣬߀ṩȼ_T5T6ԼMIE2ʵĸЧܷ늙CϵС⣬CEMP˾߀͑ṩ늙COӋԃա
CEMPЮbƷ@ATEX IEC-EX JCC늙CѱVȫĸȼױhĹIIر܊ʯͻFPSOИIŏVđã԰ȫɿIЧuȫ

CEMPķ늙CS֮һйSSҪbTF늙CSҪbTX늙Cȫڣć늙CƷABBSIEMENSSCHORCHFLENDERWEMLEESSONBALDORALSTOM EAȡCEMPļgˮƽc@Щ늙Cͬ̎һnΣһЩеI߀ԼصăݣԃrȘOߡCEMPṩʑNӭhۉmˮȵȣ늙CbƷV늙CM̵ķͷoҪ


 

FLAMEPROOF ELECTRIC
MOTORS
E3.../E4A... SERIES - IE3/IE4
GAS & DUST VERSION
? According to standards:
- IEC/EN 600079-0, 1, 7, 31
- IEC 60034-1, 2, 5, 6, 7, 8, 9, 12, 14, 30
- IEC 60072
? Ex db, Ex db eb, Ex tb, Ex tc
* Terminal box Ex db or Ex eb available
* Continuous duty or intermittment duty
? Atex category I M2, II2G, II2D, II2GD
? Gas group I, IIB, IIC
? Dust group IIIB, IIIC
? Temperature classes T3, T4, T5, T6
? Surface temperature classes (Dust)
T150C - T135C - T125C - T100C - T85C
? Protection IP55, IP56, IP65, IP66
? Frame size from 80 to 355 (IEC)
? Power 0,75 - 375 kW
? 400V, 50Hz (multi voltage 380-400-
415V/50Hz and 460V/60Hz)
? Pole 2, 4, 6, 8
? Self-cooling (IC411); Forced cooling (IC416);
Not ventilated (IC410); Totally enclosed air
over (IC418)
? Premium effi ciency IE3;
Super-premium effi cency IE4
Available IE1/IE2 (A Series)
? Certifi ed ATEX and IECEx
? Certifi ed GMEE
FLAMEPROOF ELECTRIC
MOTORS WITH BRAKE
E3.../E4D SERIES - IE3/IE4
GAS & DUST VERSION
? According to standards:
- IEC/EN 600079-0, 1, 7, 31
- IEC 60034-1, 2, 5, 6, 7, 8, 9, 12, 14, 30
- IEC 60072
* Motor enclosure Ex db (fl ameproof) and
brake in separate Ex db enclosure
* Terminal box Ex db or Ex eb available
* Multiple choice for brake torque available
* Continuous duty or intermittment duty
? Ex db, Ex db eb, Ex tb, Ex tc
? Atex category II2G, II2D, II2GD
? Gas group IIB, IIC
? Dust group IIIB, IIIC
? Temperature classes T3, T4, T5, T6
? Surface temperature classes (Dust)
T150C - T135C - T125C - T100C - T85C
? Protection IP55, IP56, IP65, IP66
? Frame size from 80 to 315 (IEC)
? Power 0,75 - 200 kW
? 400V, 50Hz (multi voltage 380-400-
420V/50Hz and 460V/60Hz)
? Pole 2, 4, 6, 8 and dual speed motor
(separate windings or Dahlander)
? Self-cooling (IC411); Forced cooling (IC416);
Not ventilated (IC410); Totally enclosed air
over (IC418)
? Premium effi ciency IE3;
Super-premium effi cency IE4
Available IE1/IE2
? Certifi ed ATEX and IECEx
? Certifi ed GMEE
NON SPARKING ELECTRIC
MOTORS
TCN SERIES - IE3/IE4
GAS & DUST VERSION
? According to standards:
- IEC/EN 600079-0, 15, 31
- IEC 60034-1, 2, 5, 6, 7, 8, 9, 12, 14, 30
- IEC 60072
? Ex -nA, Ex-tb, Ex-tc
? Atex category II3G, II3G/II2D, II3GD
? Gas group IIB, IIC
? Dust group IIIB, IIIC
? Temperature classes T3
? Max surface temperature (Dust) T200C
? Protection IP55, IP56, IP65, IP66
? Frame size from 80 to 355 (IEC)
? Power 0,75 - 375 kW
? 400V, 50Hz and 460V/60Hz
? Pole 2, 4, 6, 8
? Self-cooling (IC411); Forced cooling (IC416);
Not ventilated (IC410); Totally enclosed air
over (IC418)
? Premium effi ciency IE3;
Super-premium effi cency IE4
Available IE1/IE2
? Certifi ed ATEX and IECEx
? Certifi ed GMEEMECHANICAL
? Special fl anges and shafts
? Without terminal box with plate (cables
gland, or seal joints and conduit)
? Locked bearings, roller bearings or
special bearings
? Terminal box on side
? SPM probe (vibrations measurement)
? Double ended shafts
? Cable gland fi tted to terminal box
? Condensation drain valve
? Grade A or B vibration
? Rain cap or sun shield water shredding
disk
? Low noise
? Auxiliary terminal box
? Low (-60C) temperature motorsELETRICAL
? Special voltage and frequency
? Three phase 2 speeds
? Single phase with permanent capacitor
? Motors for tropical climates
? Electrical special designs
? Class H insulation
? Suitable for frequency converter drives
ACCESSORIES
? Forced ventilation (IC416)
? Encoders (100 C 10000 ppr)
? Bearing sensors
? Bimetallic thermal protection (NC, NO),
thermistors (PTC), platinum resistor(PT100)
? Anti-condensation heatersBRAKES
? AC disc brakes
? DC disc brakes
? Brake hand release
? Braking when not energized
ENGINEERING SERVICES
? Start-up behavior analysis
? Superimposed curve (motor + driven machine)
? Load test and thermal test as per IEC 60034-2-1
? Torque speed curve measurement
(Dynamic method)
? Insulation test
? ATEX, IEC Ex and UL approved for thermal test
? Bureau Veritas and Korean Register approved